Commit Graph

13 Commits

Author SHA1 Message Date
Alexander Alekhin
dfef04b325 Merge remote-tracking branch 'upstream/3.4' into merge-3.4 2019-02-12 17:54:40 +03:00
Vadim Pisarevsky
8f15a609af
mostly removed obsolete C API from calib3d (at least at the interface level) (#13081) 2018-11-09 16:12:22 +03:00
Wenfeng CAI
31be03a805 Merge pull request #12772 from xoox:calib-release-object
More accurate pinhole camera calibration with imperfect planar target (#12772)
43 commits:

* Add derivatives with respect to object points

Add an output parameter to calculate derivatives of image points with
respect to 3D coordinates of object points. The output jacobian matrix
is a 2Nx3N matrix where N is the number of points.

This commit introduces incompatibility to old function signature.

* Set zero for dpdo matrix before using

dpdo is a sparse matrix with only non-zero value close to major
diagonal. Set it to zero because only elements near major diagonal are
computed.

* Add jacobian columns to projectPoints()

The output jacobian matrix of derivatives with respect to coordinates of
3D object points are added. This might break callers who assume the
columns of jacobian matrix.

* Adapt test code to updated project functions

The test cases for projectPoints() and cvProjectPoints2() are updated to
fit new function signatures.

* Add accuracy test code for dpdo

* Add badarg test for dpdo

* Add new enum item for new calibration method

CALIB_RELEASE_OBJECT is used to whether to release 3D coordinates of
object points. The method was proposed in: K. H. Strobl and G. Hirzinger.
"More Accurate Pinhole Camera Calibration with Imperfect Planar Target".
In Proceedings of the IEEE International Conference on Computer Vision
(ICCV 2011), 1st IEEE Workshop on Challenges and Opportunities in Robot
Perception, Barcelona, Spain, pp. 1068-1075, November 2011.

* Add releasing object method into internal function

It's a simple extension of the standard calibration scheme. We choose to
fix the first and last object point and a user-selected fixed point.

* Add interfaces for extended calibration method

* Refine document for calibrateCamera()

When releasing object points, only the z coordinates of the
objectPoints[0].back is fixed.

* Add link to strobl2011iccv paper

* Improve documentation for calibrateCamera()

* Add implementations of wrapping calibrateCamera()

* Add checking for params of new calibration method

If input parameters are not qualified, then fall back to standard
calibration method.

* Add camera calibration method of releasing object

The current implementation is equal to or better than
https://github.com/xoox/calibrel

* Update doc for CALIB_RELEASE_OBJECT

CALIB_USE_QR or CALIB_USE_LU could be used for faster calibration with
potentially less precise and less stable in some rare cases.

* Add RELEASE_OBJECT calibration to tutorial code

To select the calibration method of releasing object points, a command
line parameter `-d=<number>` should be provided.

* Update tutorial doc for camera_calibration

If the method of releasing object points is merged into OpenCV. It will
be expected to be firstly released in 4.1, I think.

* Reduce epsilon for cornerSubPix()

Epsilon of 0.1 is a bigger one. Preciser corner positions are required
with calibration method of releasing object.

* Refine camera calibration tutorial

The hypothesis coordinates are used to indicate which distance must be
measured between two specified object points.

* Update sample calibration code method selection

Similar to camera_calibration tutorial application, a command line
argument `-dt=<number>` is used to select the calibration method.

* Add guard to flags of cvCalibrateCamera2()

cvCalibrateCamera2() doesn't accept CALIB_RELEASE_OBJECT unless overload
interface is added in the future.

* Simplify fallback when iFixedPoint is out of range

* Refactor projectPoints() to keep compatibilities

* Fix arg string "Bad rvecs header"

* Read calibration flags from test data files

Instead of being hard coded into source file, the calibration flags will
be read from test data files.
opencv_extra/testdata/cv/cameracalibration/calib?.dat must be sync with
the test code.

* Add new C interface of cvCalibrateCamera4()

With this new added C interface, the extended calibration method with
CALIB_RELEASE_OBJECT can be called by C API.

* Add regression test of extended calibration method

It has been tested with new added test data in xoox:calib-release-object
branch of opencv_extra.

* Fix assertion in test_cameracalibration.cpp

The total number of refined 3D object coordinates is checked.

* Add checker for iFixedPoint in cvCalibrateCamera4

If iFixedPoint is out of rational range, fall back to standard method.

* Fix documentation for overloaded calibrateCamera()

* Remove calibration flag of CALIB_RELEASE_OBJECT

The method selection is based on the range of the index of fixed point.
For minus values, standard calibration method will be chosen.  Values in
a rational range will make the object-releasing calibration method
selected.

* Use new interfaces instead of function overload

Existing interfaces are preserved and new interfaces are added. Since
most part of the code base are shared, calibrateCamera() is now a
wrapper function of calibrateCameraRO().

* Fix exported name of calibrateCameraRO()

* Update documentation for calibrateCameraRO()

The circumstances where this method is mostly helpful are described.

* Add note on the rigidity of the calibration target

* Update documentation for calibrateCameraRO()

It is clarified that iFixedPoint is used as a switch to select
calibration method. If input data are not qualified, exceptions will be
thrown instead of fallback scheme.

* Clarify iFixedPoint as switch and remove fallback

iFixedPoint is now used as a switch for calibration method selection. No
fallback scheme is utilized anymore. If the input data are not
qualified, exceptions will be thrown.

* Add badarg test for object-releasing method

* Fix document format of sample list

List items of same level should be indented the same way. Otherwise they
will be formatted as nested lists by Doxygen.

* Add brief intro for objectPoints and imagePoints

* Sync tutorial to sample calibration code

* Update tutorial compatibility version to 4.0
2018-10-25 19:38:55 +03:00
Alexander Alekhin
8a3c394d6a don't use constructors for C API structures 2018-09-06 14:34:16 +03:00
Alexander Alekhin
d5951bc033 build: eliminate GCC8 warnings 2018-07-16 17:24:12 +03:00
Alexander Alekhin
4a297a2443 ts: refactor OpenCV tests
- removed tr1 usage (dropped in C++17)
- moved includes of vector/map/iostream/limits into ts.hpp
- require opencv_test + anonymous namespace (added compile check)
- fixed norm() usage (must be from cvtest::norm for checks) and other conflict functions
- added missing license headers
2018-02-03 19:39:47 +00:00
Ilya Lavrenov
37789f015a deleted excess semicolons, commas 2014-01-18 01:31:33 +04:00
Roman Donchenko
2c4bbb313c Merge commit '43aec5ad' into merge-2.4
Conflicts:
	cmake/OpenCVConfig.cmake
	cmake/OpenCVLegacyOptions.cmake
	modules/contrib/src/retina.cpp
	modules/gpu/doc/camera_calibration_and_3d_reconstruction.rst
	modules/gpu/doc/video.rst
	modules/gpu/src/speckle_filtering.cpp
	modules/python/src2/cv2.cv.hpp
	modules/python/test/test2.py
	samples/python/watershed.py
2013-08-27 13:26:44 +04:00
Roman Donchenko
e9a28f66ee Normalized file endings. 2013-08-21 18:59:25 +04:00
Andrey Kamaev
e5a33723fc Move C API of opencv_calib3d to separate file 2013-04-11 21:00:17 +04:00
OpenCV Buildbot
81f826db2b Normalize line endings and whitespace 2012-10-17 15:57:49 +04:00
OpenCV Buildbot
04384a71e4 Normalize line endings and whitespace 2012-10-17 15:32:23 +04:00
Vadim Pisarevsky
061b49e0b2 reworked nearly all of the OpenCV tests (except for opencv_gpu tests) - they now use the Google Test engine. 2011-02-09 20:55:11 +00:00