added estimateTranslation3D to calib3d/ptsetreg
* added estimateTranslation3D; follows API and implementation structure for estimateAffine3D, but only allows for translation
* void variables in null function to suppress compiler warnings
* added test for estimateTranslation3D
* changed to Matx13d datatype for translation vector in ptsetreg and test; used short license in test
* removed iostream include
* calib3d: code cleanup
Image sharpness, as well as brightness, are a critical parameter for
accuracte camera calibration. For accessing these parameters for
filtering out problematic calibraiton images, this method calculates
edge profiles by traveling from black to white chessboard cell centers.
Based on this, the number of pixels is calculated required to transit
from black to white. This width of the transition area is a good
indication of how sharp the chessboard is imaged and should be below
~3.0 pixels.
Based on this also motion blur can be detectd by comparing sharpness in
vertical and horizontal direction. All unsharp images should be excluded
from calibration as they will corrupt the calibration result. The same
is true for overexposued images due to a none-linear sensor response.
This can be detected by looking at the average cell brightness of the
detected chessboard.
Lets the user choose the maximum number of iterations the robust
estimator runs for, similary to findHomography. This can significantly
improve performance (at a computational cost).
Changes:
* UMat for blur + rotate resulting in a speedup of around 2X on an i7
* support for boards larger than specified allowing to cover full FOV
* support for markers moving the origin into the center of the board
* increase detection accuracy
The main change is for supporting boards that are larger than the FOV of
the camera and have their origin in the board center. This allows
building OEM calibration targets similar to the one from intel real
sense utilizing corner points as close as possible to the image border.
This is a correction of the previously missleading documentation and a warning related to a common calibration failure described in issue 15992
* corrected incorrect description of failed calibration state.
see issue 15992
* calib3d: apply suggestions from code review by catree
Clarify stereoRectify() doc
The function stereoRectify() takes as input a coordinate transform between two cameras. It is ambiguous how it goes. I clarified that it goes from the second camera to the first.
* Doc bugfix
The documentation page StereoBinaryBM and StereoBinarySGBM says that it returns a disparity that is scaled multiplied by 16. This scaling must be undone before calling reprojectImageTo3D, otherwise the results are wrong. The function reprojectImageTo3D() could do this scaling internally, maybe, but at least the documentation must explain that this has to be done.
* calib3d: update reprojectImageTo3D documentation
* calib3d: add StereoBM/StereoSGBM into notes list
* integrated the new C++ persistence; removed old persistence; most of OpenCV compiles fine! the tests have not been run yet
* fixed multiple bugs in the new C++ persistence
* fixed raw size of the parsed empty sequences
* [temporarily] excluded obsolete applications traincascade and createsamples from build
* fixed several compiler warnings and multiple test failures
* undo changes in cocoa window rendering (that was fixed in another PR)
* fixed more compile warnings and the remaining test failures (hopefully)
* trying to fix the last little warning
More accurate pinhole camera calibration with imperfect planar target (#12772)
43 commits:
* Add derivatives with respect to object points
Add an output parameter to calculate derivatives of image points with
respect to 3D coordinates of object points. The output jacobian matrix
is a 2Nx3N matrix where N is the number of points.
This commit introduces incompatibility to old function signature.
* Set zero for dpdo matrix before using
dpdo is a sparse matrix with only non-zero value close to major
diagonal. Set it to zero because only elements near major diagonal are
computed.
* Add jacobian columns to projectPoints()
The output jacobian matrix of derivatives with respect to coordinates of
3D object points are added. This might break callers who assume the
columns of jacobian matrix.
* Adapt test code to updated project functions
The test cases for projectPoints() and cvProjectPoints2() are updated to
fit new function signatures.
* Add accuracy test code for dpdo
* Add badarg test for dpdo
* Add new enum item for new calibration method
CALIB_RELEASE_OBJECT is used to whether to release 3D coordinates of
object points. The method was proposed in: K. H. Strobl and G. Hirzinger.
"More Accurate Pinhole Camera Calibration with Imperfect Planar Target".
In Proceedings of the IEEE International Conference on Computer Vision
(ICCV 2011), 1st IEEE Workshop on Challenges and Opportunities in Robot
Perception, Barcelona, Spain, pp. 1068-1075, November 2011.
* Add releasing object method into internal function
It's a simple extension of the standard calibration scheme. We choose to
fix the first and last object point and a user-selected fixed point.
* Add interfaces for extended calibration method
* Refine document for calibrateCamera()
When releasing object points, only the z coordinates of the
objectPoints[0].back is fixed.
* Add link to strobl2011iccv paper
* Improve documentation for calibrateCamera()
* Add implementations of wrapping calibrateCamera()
* Add checking for params of new calibration method
If input parameters are not qualified, then fall back to standard
calibration method.
* Add camera calibration method of releasing object
The current implementation is equal to or better than
https://github.com/xoox/calibrel
* Update doc for CALIB_RELEASE_OBJECT
CALIB_USE_QR or CALIB_USE_LU could be used for faster calibration with
potentially less precise and less stable in some rare cases.
* Add RELEASE_OBJECT calibration to tutorial code
To select the calibration method of releasing object points, a command
line parameter `-d=<number>` should be provided.
* Update tutorial doc for camera_calibration
If the method of releasing object points is merged into OpenCV. It will
be expected to be firstly released in 4.1, I think.
* Reduce epsilon for cornerSubPix()
Epsilon of 0.1 is a bigger one. Preciser corner positions are required
with calibration method of releasing object.
* Refine camera calibration tutorial
The hypothesis coordinates are used to indicate which distance must be
measured between two specified object points.
* Update sample calibration code method selection
Similar to camera_calibration tutorial application, a command line
argument `-dt=<number>` is used to select the calibration method.
* Add guard to flags of cvCalibrateCamera2()
cvCalibrateCamera2() doesn't accept CALIB_RELEASE_OBJECT unless overload
interface is added in the future.
* Simplify fallback when iFixedPoint is out of range
* Refactor projectPoints() to keep compatibilities
* Fix arg string "Bad rvecs header"
* Read calibration flags from test data files
Instead of being hard coded into source file, the calibration flags will
be read from test data files.
opencv_extra/testdata/cv/cameracalibration/calib?.dat must be sync with
the test code.
* Add new C interface of cvCalibrateCamera4()
With this new added C interface, the extended calibration method with
CALIB_RELEASE_OBJECT can be called by C API.
* Add regression test of extended calibration method
It has been tested with new added test data in xoox:calib-release-object
branch of opencv_extra.
* Fix assertion in test_cameracalibration.cpp
The total number of refined 3D object coordinates is checked.
* Add checker for iFixedPoint in cvCalibrateCamera4
If iFixedPoint is out of rational range, fall back to standard method.
* Fix documentation for overloaded calibrateCamera()
* Remove calibration flag of CALIB_RELEASE_OBJECT
The method selection is based on the range of the index of fixed point.
For minus values, standard calibration method will be chosen. Values in
a rational range will make the object-releasing calibration method
selected.
* Use new interfaces instead of function overload
Existing interfaces are preserved and new interfaces are added. Since
most part of the code base are shared, calibrateCamera() is now a
wrapper function of calibrateCameraRO().
* Fix exported name of calibrateCameraRO()
* Update documentation for calibrateCameraRO()
The circumstances where this method is mostly helpful are described.
* Add note on the rigidity of the calibration target
* Update documentation for calibrateCameraRO()
It is clarified that iFixedPoint is used as a switch to select
calibration method. If input data are not qualified, exceptions will be
thrown instead of fallback scheme.
* Clarify iFixedPoint as switch and remove fallback
iFixedPoint is now used as a switch for calibration method selection. No
fallback scheme is utilized anymore. If the input data are not
qualified, exceptions will be thrown.
* Add badarg test for object-releasing method
* Fix document format of sample list
List items of same level should be indented the same way. Otherwise they
will be formatted as nested lists by Doxygen.
* Add brief intro for objectPoints and imagePoints
* Sync tutorial to sample calibration code
* Update tutorial compatibility version to 4.0