Update USAC #23078
### Pull Request Readiness Checklist
- [x] I agree to contribute to the project under Apache 2 License.
- [x] To the best of my knowledge, the proposed patch is not based on a code under GPL or another license that is incompatible with OpenCV
- [x] The PR is proposed to the proper branch
- [x] There is a reference to the original bug report and related work
- [x] There is accuracy test, performance test and test data in opencv_extra repository, if applicable
Patch to opencv_extra has the same branch name.
- [x] The feature is well documented and sample code can be built with the project CMake
Add undistortImagePoints function
* Add undistortImagePoints function
undistortPoints has unclear interface and additional functionality. New function computes only undistorted image points position
* Add undistortImagePoints test
* Add TermCriteria
* Fix layout
Recover pose from different cameras (version 2)
* add recoverPose for two different cameras
* Address review comments from original PR
* Address new review comments
* Rename private api
Co-authored-by: tompollok <tom.pollok@gmail.com>
Co-authored-by: Zane <zane.huang@mail.utoronto.ca>
Update to initInverseRectificationMap()
* update to initInverseRectificationMap() documentation
* Restructured Calib3d_InitInverseRectificationMap unit test per feedback from alalek
* whitespace
Fixed trailing whitespace
Update to initInverseRectificationMap documentation for clarity
Added test case for initInverseRectificationMap()
Updated documentation.
Fixed whitespace error in docs
Small update to test function
Now passes success_error_level
final update to inverseRectification documentation
- Added missing documentation for the CALIB_FIX_FOCAL_LENGTH flag
- Removed erroneous information about the number of distortion coefficients
returned
- Added some missing @ref tags
* Added CALIB_FIX_FOCAL_LENGTH to fisheye calibration #13450
Sometimes you want to calibrate just the principal point of a camera, or just the distortion coefficients. In this case, you can pass the CALIB_FIX_FOCAL_LENGTH flag to keep Fx and Fy
* Added test for CALIB_FIX_FOCAL_LENGTH option in fisheye callinration.
Fisheye test has been updated to use new enum cv::fisheye::CALIB_ZERO_DISPARITY and included CV_StaticAssert(...) to ensure cv::CALIB_ZERO_DISPARITY == cv::fisheye::CALIB_ZERO_DISPARITY.
- detect case with infinite loop and raise NoConv exception
- handle such exception
- add support for case with missing `blobDetector` (image contains Point2f array of candidates)
- add regression test
- undone rectification for "failed" detections too
- drop redirectError() usage
Added SQPnP algorithm to SolvePnP
* Added sqpnp
* Fixed test case
* Added fix for duplicate point checking and inverse func reuse
* Changes for 3x speedup
Changed norm method (significant speed increase), changed nearest rotation computation to FOAM
* Added symmetric 3x3 inverse and unrolled loops
* Fixed error with SVD
* Fixed error from with indices
Indices were initialized negative. When nullspace is large, points coplanar, and rotation near 0, indices not changed.